Trane troubleshootingTrane fault codes
Each code links to the manual page it comes from. Pick the family that matches the nameplate.
410A Systems / Air Handlers / GAM5 / GAM5 Service Facts
410A Systems / Air Handlers / TAM / TAM7 / TAM7-SF-2E-EN
410A Systems / Air Handlers / TAM / TAM8 / AM8-SF-1A
410A Systems / 2 Stage Systems / 4TWZ0048B-SF-1
4TWV8- Service Facts
System Alert Guide 529992050
- CFG.008.02MISSING INDOOR STAGE CONFIGURATION FAULT
- ERR.001.04PRESSURE SWITCH #1 OPEN
- ERR.004.00LOW FLAME SENSOR CURRENT
- ERR.010.00IGNITOR OPEN / OUT OF RANGE OR IGNITOR CIRCUIT OPEN
- ERR.067.04DOME TEMPERATURE SENSOR FAULT COOLING
- ERR.068.01DEFROST FAULT B AND/OR C
- ERR.089.00EQUIPMENT MISSING
- ERR.090.02EXCESSIVE COMMUNICATION ERRORS
- ERR.104.01ELECTRIC HEAT RELAY STUCK CLOSED
- ERR.105.02HEAT RELAY AND HEAT INTERLOCK RELAY ON ERROR
- ERR.107.01HIGH VOLTAGE ARC SOFT LOCKOUT
- ERR.114.01PERSONALITY MODULE COMPRESSOR SIZE MISMATCH
- ERR.123.00ELECTRIC HEAT CONFIGURATION FAULT
- ERR.126.00EQUIPMENT CHANGE ALERT
- ERR.159.00AIRFLOW CONTROL UNIT BUS COMM ERROR
- ERR.166.00LOW SUPERHEAT OCCURRENCES COOLING
- ERR.177.03DRIVE HARDWARE OVERCURRENT
- ERR.181.04COMPRESSOR STALL DETECTION FAULT
- ERR.182.00STARTUP ALGORITHM FAULT
- ERR.184.01COMPRESSOR DOME TEMPERATURE PROTECTION - HIGH SPEED
- ERR.184.08UNIVERSAL HARD LOCKOUT
- ERR.185.06DRIVE CURRENT PROTECT UP
- ERR.189.00CONTROL BOARD HIGH TEMPERATURE DERATE
- SOP.004.03ZONE/WIRELESS RH SENSOR FAULT
- SOP.004.04INTERNET OUTDOOR TEMPERATURE FAULT
- SOP.004.51DIFFERENTIAL STATIC PRESS SENSOR FAULT
- SOP.004.54DISCHARGE TEMP SENSOR LOCKOUT
Trane Alert Codes (ComfortLink II Alarm ID list)
- CL.188.05Voltage VEE low
- CL2.018.00Control Fault
- CL2.022.00Recycle Lockout
- CL2.033.00Polarity Error
- CL2.068.00Defrost Fault A
- CL2.080.02Reduced capacity
- CL2.090.00Blower Comm CRC
- CL2.091.01Inducer Comm Error
- CL2.091.02System Comm Error
- CL2.101.00Y1 Off Error
- CL2.153.00Cycling limit open
- CL2.164.00Indoor EEV error
- CL2.164.02Outdoor EEV error
- CL2.175.00Limp along mode
- CL2.180.00Supply voltage failure
- CL2.181.15ADC current exceeded
- CL2.185.00Protection derating fault
- CL2.185.07Protection derating fault
- CL2.186.00Protection derating fault
Upflow/Horizontal and Dedicated Downflow Gas-Fired, Direct/Non-Direct Vent, Modulating Condensing Variable Speed Furnaces with Variable Speed Draft Inducer
Upflow/Horizontal and Dedicated Downflow Gas-Fired, Direct/Non-Direct Vent, 2-Stage Condensing Variable Speed Furnaces A952V
FNR-SVN001A-EN_10182025
Installation, Operation, and Maintenance - Link Communicating or 24 Volt Gas-Fired 2 Stage Induced Draft Furnaces with Variable Speed Motor S8V2-C
19-23 Seer 2 Single Zone Ductless Mini-Split Heat Pump
COR-SVX002B-EN_01302026