Goodman troubleshootingGoodman fault codes
Each code links to the manual page it comes from. Pick the family that matches the nameplate.
Installation Instructions IO-453B
Service Manual sm-rsd6432301
- A0External protection device activated; Force shutdown device (e.g. smoke detector) activated; A2L refrigerant leakage detected; A2L refrigerant leakage evaluation and mitigation; High CO2 concentration; High supply air temperature; Low supply air temperature; High indoor humidity; High indoor temperature
- A6Insufficient indoor airflow; Economizer feedback missing; Economizer damper opening alarm; Economizer supply air temperature alarm
- A9Electronic expansion valve (IEV) coil disconnected; Electronic expansion valve (IEV) coil driver failure; Electronic expansion valve (IEV) coil overcurrent
- CASupply air temperature sensor (SAT) failure; Supply air temperature sensor (SAT) alarm; Indoor coil leaving air thermistor (LCT) failure(Only for HGRH model)
- JCSuction pressure transducer (SPTR) failure : Open; Suction pressure transducer (SPTR) failure : Short
- L1Overcurrent protection activated : INVERTER PCB (A3P); Current sensor 1 failure : INVERTER PCB (A3P); Current sensor 2 failure : INVERTER PCB (A3P); IGBT error: INVERTER PCB (A3P); Jumper settings error: INVERTER PCB (A3P); INVERTER PCB (A3P) EEPROM failure; IPM failure : INVERTER PCB (A3P)
- LCCommunication fault: MAIN PCB(A1P) - INVERTER PCB(A3P); Communication fault: MAIN PCB(A1P) - FAN PCB(A4P); Communication fault: MAIN PCB(A1P) - FAN PCB(A5P); Communication fault: MAIN PCB(A1P) - SUB PCB(A6P)
- U2Shortage of INVERTER PCB (A3P) power supply voltage
- UHUnidentified automatic address; Communication fault between BACnet PCB and INDOOR PCB(A8P)
CDVS96 / GR9S96 / VR9S96 series
Installation Instructions IOD-2024E
GD9T80 / GD9T96 / GR9S96 / GR9T80 / GR9T96 / VR9S96 series
Service Manual rs6200007r23
CDVS96 / GCVC96 / GD9T80 / GD9T96 / GDVM97 / GDVT80 / GDVT96 / GMVC96 / GR9S96 / GR9T80 / GR9T96 / GRVM97 / GRVT80 / GRVT96 / VR9S96 series
- EE0Furnace lockout due to excessive number of ignition "retries" (3 total). Failure to establish flame. Loss of flame after establishment.
- EE1Low stage pressure switch circuit is closed at start of heating cycle Low stage pressure switch contacts sticking Short in pressure switch circuit wiring
- EEAPolarity of 115 volt AC is reversed Poor unit ground
CDVS96 / GCVC96 / GDVM97 / GDVT80 / GDVT96 / GMVC96 / GRVM97 / GRVT80 / GRVT96 series
GD9T80 / GD9T96 / GR9T80 / GR9T96 series