Lennox troubleshootingLennox fault codes
Each code links to the manual page it comes from. Pick the family that matches the nameplate.
EL180UHNEK Upflow/Horizontal ULNOx Service
EL296D / EL297D series
- E115Low 24V - Control will restart if the error recovers.
- E125Control failed self-check, internal error, failed hardware. Will restart if error recovers. Integrated control not communicating. Covers hardware errors (flame sense circuit faults, pin shorts, etc.).
- E228Combustion air inducer calibration failure
- E290Ignitor circuit fault - Failed ignitor or triggering circuitry.
- E310Discharge error temperature sensor failure. Only shown if shorted or out of range.
- E312Restricted air flow in cooling or continu- ous fan mode is lower than cfm setting.
- E347No 24 Volt output on Y1 of ”integrated control” with non communicating outdoor unit.
- E370Interlock switch sensed open for 2 min- utes.
SLP99DFVK Downflow Service
Chiller Fan Coil Control Kit Installation manual | VCTRL04P-1
EL296D / EL297D / ML296D / ML296U / ML297D / ML297U series
EL297D / ML296D / ML296U / ML297D / ML297U series
SL25KCV | UNIT INFORMATION | Service Literature
MMLD018-048S6S, MMPD024-048S6S Outdoor Single Zone R-32 Instructions
EL296D / EL297D / MMLD020S6M-1P / MMLD024S6M-1P / MMLD030S6M-1P / MMLD036S6M-1P / MMPD020S6M-1P / MMPD024S6M-1P / MMPD036S6M-1P / MMPD048S6M-1P series
MMLD009S6S-1P / MMLD012S6S-1P / MMLD024S6S-1P / MMLD030S6S-1P / MMLD036S6S-1P / MMLD048S6S-1P / MMPD018S6S-1P / MMPD024S6S-1P / MMPD030S6S-1P / MMPD036S6S-1P / MMPD048S6S-1P series
MMLD009S6S-1P / MMLD012S6S-1P / MMLD020S6M-1P / MMLD024S6M-1P / MMLD024S6S-1P / MMLD030S6M-1P / MMLD030S6S-1P / MMLD036S6M-1P / MMLD036S6S-1P / MMLD048S6S-1P / MMPD018S6S-1P / MMPD020S6M-1P / MMPD024S6M-1P / MMPD024S6S-1P / MMPD030S6S-1P / MMPD036S6M-1P / MMPD036S6S-1P / MMPD048S6M-1P / MMPD048S6S-1P series
UNIT INFORMATION UNIT INFORMATION | SL297UHNV Corp 1802-L1 Revised 04/2024 | ServiceLiterature
EL297D / MMLD020S6M-1P / MMLD024S6M-1P / MMLD030S6M-1P / MMLD036S6M-1P / MMPD020S6M-1P / MMPD024S6M-1P / MMPD036S6M-1P / MMPD048S6M-1P series
EL297D series
EL21KLV | UNIT INFORMATION | Service Literature
- E482Compressor Suction Temperature sensor has malfunctioned. Check temperature sensor resistance in the applicable Installation and Service Procedure Manual. Nominal resistance is 10K ohms at 77°F. Compressor speed limited to 70 hz.
- E486System superheat below 3 degrees F for more than 10 minutes. Heat pump heating operation stopped.
MMLD020S6M-1P / MMLD024S6M-1P / MMLD030S6M-1P / MMLD036S6M-1P / MMPD020S6M-1P / MMPD024S6M-1P / MMPD036S6M-1P / MMPD048S6M-1P series