Upflow/Horizontal and Dedicated Downflow Gas-Fired, Direct/Non-Direct Vent, 2-Stage Condensing Variable Speed Furnaces A952VTrane e10 fault code
Communication error between variable speed inducer and blower motor microprocessor
What the manual says
Communication error between variable speed inducer and blower motor microprocessor
Checks from the manual
- 1. 1st stage gas valve not energized when it should be 2. 1st stage gas valve relay stuck closed 3. 2nd stage gas valve relay stuck closed 4. 2nd stage gas valve energized when it should not be 5. 2nd stage gas valve not energized when it should be e!2 | Open fuse e!3 | Blower HP/OEM ID e!4 | No PM and local copy bad e!s | Both of unit Data File in PM and local Unit Data File are corrupt e!7 | Blower motor no communication response e!8 | Blower communication failure on the control
Source
Upflow/Horizontal and Dedicated Downflow Gas-Fired, Direct/Non-Direct Vent, 2-Stage Condensing Variable Speed Furnaces A952V, p. 89
e10 | Communication error between variable speed inducer and blower motor microprocessor e!! | 1. 1st stage gas valve not energized when it should be 2. 1st stage gas valve relay stuck closed 3. 2nd stage gas valve relay stuck closed 4. 2nd stage gas valve energized when it should not be 5. 2nd stage gas valve not energized when it should be e!2 | Open fuse e!3 | Blower HP/OEM ID e!4 | No PM and local copy bad e!s | Both of unit Data File in PM and local Unit Data File are corrupt e!7 | Blower motor no communication response e!8 | Blower communication failure on the control
Other Trane codes in this family
Ask about your unit
Last checked 2026-11-18 against Upflow/Horizontal and Dedicated Downflow Gas-Fired, Direct/Non-Direct Vent, 2-Stage Condensing Variable Speed Furnaces A952V.
Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.