Trane Alert Codes (ComfortLink II Alarm ID list)Trane CL2.068.00 fault code
Defrost Fault A
What the manual says
Defrost Fault A
Source
Trane Alert Codes (ComfortLink II Alarm ID list), p. 3
CL2.068.00 | Normal | Fault A | Defrost Fault A | Defrost Fault A **Low delta T or low heat pump capacity | Inoperative compressor Shorted coil sensor Open ambient sensor | | CL2.068.01 | Normal | Fault B/C | Defrost Fault B and/or C | Defrost Fault B and/or C **Very high delta T **Defrost terminated at least 10 times in a row on maximum override time (15 minutes) instead of temperature | SOV stuck in heat mode Outdoor fan failure Open coil sensor Shorted ambient air sensor | | CL2.068.02 | Normal | Fault A(B/C) | Defrost Fault A and (B and/or C) | Defrost Fault A and (B and/or C) **60 or more A faults and 1 or more B faults **60 or more A faults and 1 or more C