Trane Alert Codes (ComfortLink II Alarm ID list)Trane CL2.090.00 fault code
Blower Comm CRC
What the manual says
Blower Comm CRC
Source
Trane Alert Codes (ComfortLink II Alarm ID list), p. 4
CL2.090.00 | Normal | BLW COMM CRC | Blower Comm CRC | Blower motor unrecognized response **Communication with blower motor cannot be established | Reboot line voltage to indoor unit and check to see if fault clears **If error does not clear contact your local field rep for additional support | | CL2.090.01 | Normal | IND COMM CRC | Inducer Comm CRC | Inducer motor unrecognized response **Communication with draft inducer motor cannot be established | Reboot line voltage to furnace and check to see if fault clears **If error does not clear contact your local field rep for additional support | | CL2.090.02 | Normal | SYS COM ERR | System Comm Error/CRC | Excessive communication errors **Comfort control is continually attempting to communicate with no idle detected (bus busy) | R and B wiring reversed at comfort control or indoor unit If a communicating air cleaner is installed, remove (D) data wire and check to see if fault clears **If error does not clear contact your local field rep for additional support | | CL2.091.00 | Critical | Blw Comm Err | Blower Comm Error | (CLII / AccuLink units only) Loss of communication between serial communicating blower motor and control board (3-Stage/Modulating Furnaces only) Corrupted signal between integrated furnace control board and inducer drive control board can also cause this fault | No line voltage to blower motor or inducer motor control board **Furnace 115vAC Air Handler 230vAC Faulty low voltage connection between control board and blower motor **12vDC should be measured between 12v pin and GND pin on control board and at terminals 1 & 4 at blower motor low voltage plug Perform 24volt “Go/No-Go Test” by applying 24vAC to pins 3 & 4 at blower motor low voltage harness **If motor runs replace control board if motor does not run and motor harness tests good, replace motor assembly (3-Stage/Modulating Furnace only) Disconnect 4-pin connector from E9 on furnace control board, cycle power, then test blower operation **If blower runs, the inducer drive control board is causing the fault | | CL2.091.01 | Critical | Ind Comm Err | Inducer Comm Error | Loss of communication between furnace control board and draft inducer motor control board | Faulty connection or harness between furnace control board and draft inducer motor control board **On a call for heat the GREEN COM LED on the inducer motor control board should be flashing to confirm communication with furnace control board Faulty inducer drive board | |
Ask about your unit
Last checked 2026-11-18 against Trane Alert Codes (ComfortLink II Alarm ID list).
Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.