Skip to content

System Alert Guide 529992050Trane ERR.177.03 fault code

DRIVE HARDWARE OVERCURRENT

What the manual says

DRIVE HARDWARE OVERCURRENT

Source

System Alert Guide 529992050, p. 35

ERR.177.03
 | DRIVE HARDWARE
OVERCURRENT | For models 4TWV, 4TTV, 4A6V
& 4A7V: Drive output current
exceeds internal limit set for
current sensor (5 minute soft
lockout)
For model 4TWL90: APFC over
temperature
For all models listed above: 5
occurrences in approximately
5 hours will result in Drive
Overcurrent Hard Lockout (177.04)
and Universal Hard Lockout
(184.08) | For models 4TWV, 4TTV, 4A6V & 4A7V: Run drive
diagnostics and consult Variable Speed Outdoor Unit
Technical Service Manual for diagnosis
- Call for tech support, record failure mode for warranty
claim before replacing drive
For model 4TWL90: High load condition in cooling
Compressor started at end of preheat cycle (normal
operation)
Ask about your unit

Last checked 2026-11-18 against System Alert Guide 529992050.

Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.