System Alert Guide 529992050Trane ERR.177.03 fault code
DRIVE HARDWARE OVERCURRENT
What the manual says
DRIVE HARDWARE OVERCURRENT
Source
System Alert Guide 529992050, p. 35
ERR.177.03 | DRIVE HARDWARE OVERCURRENT | For models 4TWV, 4TTV, 4A6V & 4A7V: Drive output current exceeds internal limit set for current sensor (5 minute soft lockout) For model 4TWL90: APFC over temperature For all models listed above: 5 occurrences in approximately 5 hours will result in Drive Overcurrent Hard Lockout (177.04) and Universal Hard Lockout (184.08) | For models 4TWV, 4TTV, 4A6V & 4A7V: Run drive diagnostics and consult Variable Speed Outdoor Unit Technical Service Manual for diagnosis - Call for tech support, record failure mode for warranty claim before replacing drive For model 4TWL90: High load condition in cooling Compressor started at end of preheat cycle (normal operation)
Ask about your unit
Last checked 2026-11-18 against System Alert Guide 529992050.
Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.