System Alert Guide 529992050Trane ERR.181.04 fault code
COMPRESSOR STALL DETECTION FAULT
What the manual says
COMPRESSOR STALL DETECTION FAULT
Source
System Alert Guide 529992050, p. 38
ERR.181.04 | COMPRESSOR STALL DETECTION FAULT | Compressor locked rotor condition has been detected (5 minute soft lockout) Drive Software Overcurrent (177.02) may accompany this alarm | Run drive diagnostics and consult Variable Speed Outdoor Unit Technical Service Manual for diagnosis Compressor full of liquid - After running drive diagnostics, wait at least 1 hour with high voltage applied to unit allowing preheat operation to dissipate refrigerant from compressor Verify system is not grossly overcharged and that service valves are open Potential bad compressor
Ask about your unit
Last checked 2026-11-18 against System Alert Guide 529992050.
Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.