System Alert Guide 529992050Trane ERR.181.04 fault code

COMPRESSOR STALL DETECTION FAULT

What the manual says

COMPRESSOR STALL DETECTION FAULT

Source

System Alert Guide 529992050, p. 38

ERR.181.04
 | COMPRESSOR STALL
DETECTION FAULT | Compressor locked rotor
condition has been detected (5
minute soft lockout)
Drive Software Overcurrent
(177.02) may accompany this alarm | Run drive diagnostics and consult Variable Speed Outdoor
Unit Technical Service Manual for diagnosis
Compressor full of liquid
- After running drive diagnostics, wait at least 1 hour with
high voltage applied to unit allowing preheat operation to
dissipate refrigerant from compressor
Verify system is not grossly overcharged and that service
valves are open
Potential bad compressor
Ask about your unit

Last checked 2026-11-18 against System Alert Guide 529992050.

Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.