Skip to content

System Alert Guide 529992050Trane ERR.184.01 fault code

COMPRESSOR DOME TEMPERATURE PROTECTION - HIGH SPEED

What the manual says

COMPRESSOR DOME TEMPERATURE PROTECTION - HIGH SPEED

Source

System Alert Guide 529992050, p. 41

ERR.184.01
 | COMPRESSOR DOME
TEMPERATURE
PROTECTION - HIGH
SPEED | Compressor high temperature
protection at high speed (15
minute soft lockout)
5 occurrences within approx. 5
hours will result in Universal Hard
Lockout (184.08) | Low charge
Restricted metering device. Check for high superheat.
- Indoor expansion valve in cooling mode
- Outdoor expansion valve in heating mode
Restricted condenser airflow in cooling mode
Check dome temperature sensor calibration
High indoor ambient in heat mode (Indoor set point above
80F).
- Increase ID airflow
Ask about your unit

Last checked 2026-11-18 against System Alert Guide 529992050.

Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.

No card