EL296D / EL297D seriesLennox E310 fault code (EL296D / EL297D)
Discharge error temperature sensor failure. Only shown if shorted or out of range.
What the manual says
Discharge error temperature sensor failure. Only shown if shorted or out of range.
Models and series
Listed for: EL296D, EL297D.
Checks from the manual
- Compare outdoor sensor resistance to temperature/ re- sistance charts in installation instructions. Replace sensor if necessary. Cleared in Communicating mode: 30 sec- onds after fault recovered. In Non- Communicating mode: Cleared after the current heat call is completed.
Source
EL296DFV Downflow Variable Communicating Service, p. 18
E310 | Discharge error temperature sensor failure. Only shown if shorted or out of range. | Compare outdoor sensor resistance to temperature/ re- sistance charts in installation instructions. Replace sensor if necessary. Cleared in Communicating mode: 30 sec- onds after fault recovered. In Non- Communicating mode: Cleared after the current heat call is completed.