EL296D / EL297D / ML296D / ML296U / ML297D / ML297U seriesLennox E311 fault code (EL296D / EL297D / ML296D / ML296U / ML297D / ML297U)

Heat rate reduced to match indoor blower air flow.

What the manual says

Heat rate reduced to match indoor blower air flow.

Models and series

Listed for: EL296D, EL297D, ML296D, ML296U, ML297D, ML297U.

Checks from the manual

  1. Warning Only. Furnace blower in cutback mode due to restricted airflow. Reduce firing rate every 60 seconds to match available CFM. Check filter and duct system. To clear, replace filter if needed or repair/ add duct. 2-stage controls will reduce firing rate to 1st stage. Clears when heat call finishes successfully.

Source

EL296DFV Downflow Variable Communicating Service, p. 18

E311 | Heat rate reduced to match indoor blower air flow. | Warning Only. Furnace blower in cutback mode due to
restricted airflow. Reduce firing rate every 60 seconds to
match available CFM. Check filter and duct system. To
clear, replace filter if needed or repair/ add duct. 2-stage
controls will reduce firing rate to 1st stage. Clears when
heat call finishes successfully.