MMLD018-048S6S, MMPD024-048S6S Outdoor Single Zone R-32 InstructionsLennox E381 fault code

INVERTER PCB overheat error

What the manual says

INVERTER PCB overheat error

Source

MMLD018-048S6S, MMPD024-048S6S Outdoor Single Zone R-32 Instructions, p. 51

No. | Error
Code | Meaning | Remarks
14 | E206 | Main PBA - other PBA communication error
(Some of PBA communication)
C002 : Fan PCB communication error
C003 : INV1 communication error | 1. Check Main PBA connectors
2. Check other PBA connectors
3. Change other PBA
15 | E221 | Error on outdoor temperature sensor (Short or Open) | Check Outdoor sensor Open / Short
16 | E231 | Error on outdoor COND OUT sensor (Short or Open) | Check Cond-Out sensor Open / Short
17 | E251 | Error on discharge temperature sensor of compressor 1
(Short or Open) | Check Discharge sensor Open / Short
18 | E320 | Error on OLP sensor (Short or Open) | Check OLP sensor Open / Short
19 | E321 | Error on ESC IN temperature sensor (Short or Open) | Check ESC IN sensor Open / Short
20 | E322 | Error on ESC OUT temperature sensor (Short or Open) | Check ESC OUT sensor Open / Short
21 | E381 | INVERTER PCB overheat error | Check Outdoor Inverter PBA
22 | E383 | Outdoor Fan#1 PCB overheat error | 1. Change motor
2. Change INV PCB
23 | E403 | Compressor down due to freeze protection control | Check Outdoor Cond.
24 | E404 | System stops due to overload protection control | Check Comp. when it starts
25 | E416 | System stops due to discharge temperature | -
26 | E422 | Blockage detected on high pressure pipe during cooling
operation | 1. Check if the service valve is open
2. Check for refrigerant leakage (pipe
connections, heat exchanger) and
charge refrigerant if necessary
3. Check if there's any blockage on
the refrigerant cycle (indoor unit/
outdoor unit)
4. Check if additional refrigerant has
been added after pipe extension
27 | E425 | Reverse phase or open phase | Check whether 3 phase is reversed
or opened.
28 | E440 | Heating operation restricted at outdoor temperature over
Theat high value (default:30°C)
_ | 1. Check the range of temperature
limited for heating operation
2.Check the outdoor temperature
sensor
29 | E441 | Cooling operation restricted at outdoor temperature
below Tcool low value (default:0°C)
_ | 1. Check the range of temperature
limited for cooling operation
2. Check the outdoor temperature
sensor
30 | E446 | Outdoor Fan#1 motor Operation error | 1. Change motor
2. Change INV PCB