MMLD018-048S6S, MMPD024-048S6S Outdoor Single Zone R-32 InstructionsLennox E381 fault code
INVERTER PCB overheat error
What the manual says
INVERTER PCB overheat error
Source
MMLD018-048S6S, MMPD024-048S6S Outdoor Single Zone R-32 Instructions, p. 51
No. | Error Code | Meaning | Remarks 14 | E206 | Main PBA - other PBA communication error (Some of PBA communication) C002 : Fan PCB communication error C003 : INV1 communication error | 1. Check Main PBA connectors 2. Check other PBA connectors 3. Change other PBA 15 | E221 | Error on outdoor temperature sensor (Short or Open) | Check Outdoor sensor Open / Short 16 | E231 | Error on outdoor COND OUT sensor (Short or Open) | Check Cond-Out sensor Open / Short 17 | E251 | Error on discharge temperature sensor of compressor 1 (Short or Open) | Check Discharge sensor Open / Short 18 | E320 | Error on OLP sensor (Short or Open) | Check OLP sensor Open / Short 19 | E321 | Error on ESC IN temperature sensor (Short or Open) | Check ESC IN sensor Open / Short 20 | E322 | Error on ESC OUT temperature sensor (Short or Open) | Check ESC OUT sensor Open / Short 21 | E381 | INVERTER PCB overheat error | Check Outdoor Inverter PBA 22 | E383 | Outdoor Fan#1 PCB overheat error | 1. Change motor 2. Change INV PCB 23 | E403 | Compressor down due to freeze protection control | Check Outdoor Cond. 24 | E404 | System stops due to overload protection control | Check Comp. when it starts 25 | E416 | System stops due to discharge temperature | - 26 | E422 | Blockage detected on high pressure pipe during cooling operation | 1. Check if the service valve is open 2. Check for refrigerant leakage (pipe connections, heat exchanger) and charge refrigerant if necessary 3. Check if there's any blockage on the refrigerant cycle (indoor unit/ outdoor unit) 4. Check if additional refrigerant has been added after pipe extension 27 | E425 | Reverse phase or open phase | Check whether 3 phase is reversed or opened. 28 | E440 | Heating operation restricted at outdoor temperature over Theat high value (default:30°C) _ | 1. Check the range of temperature limited for heating operation 2.Check the outdoor temperature sensor 29 | E441 | Cooling operation restricted at outdoor temperature below Tcool low value (default:0°C) _ | 1. Check the range of temperature limited for cooling operation 2. Check the outdoor temperature sensor 30 | E446 | Outdoor Fan#1 motor Operation error | 1. Change motor 2. Change INV PCB
Other Lennox codes in this family
Ask about your unit
Last checked 2026-11-18 against MMLD018-048S6S, MMPD024-048S6S Outdoor Single Zone R-32 Instructions.
Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.