EL297D / MMLD020S6M-1P / MMLD024S6M-1P / MMLD030S6M-1P / MMLD036S6M-1P / MMPD020S6M-1P / MMPD024S6M-1P / MMPD036S6M-1P / MMPD048S6M-1P seriesLennox E404 fault code

LSOM - Compressor rotor locked. Com­ pressor short-cycling. (Running less than 4 minutes).

What the manual says

LSOM - Compressor rotor locked. Com­ pressor short-cycling. (Running less than 4 minutes).

Models and series

Listed for: EL297D, MMLD020S6M-1P, MMLD024S6M-1P, MMLD030S6M-1P, MMLD036S6M-1P, MMPD020S6M-1P, MMPD024S6M-1P, MMPD036S6M-1P, MMPD048S6M-1P.

Checks from the manual

  1. Compressor rotor locked up due to run capacitor short, bearings are seized, excessive liquid refrigerant, etc. Clears the error after 4 consecutive normal run cycles or after power reset.

Troubleshooting from the service manual

  1. 12. Outdoor unit freezing detection (at the stop of the compressor): E403 / Outdoor overload protection control (at the stop of the compressor): E404

    Outdoor overload protection control (at the stop of the compressor): E404 - Check whether the fan and the motor operate normally. - Check the operation of EEV. - Check the temperature sensor of the indoor unit heat exchanger. - Check the indoor unit inlet blockage.

    Lennox Powered by Samsung Mini-Split (AC) Service, p. 160

Source

EL297UHV Upflow/Horizontal Variable Communicating Service, p. 42

E404 | LSOM - Compressor rotor locked. Com­
pressor short-cycling. (Running less than
4 minutes). | Compressor rotor locked up due to run capacitor short, bearings
are seized, excessive liquid refrigerant, etc. Clears the error after 4
consecutive normal run cycles or after power reset.
Ask about your unit

Last checked 2026-11-18 against EL297UHV Upflow/Horizontal Variable Communicating Service.

Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.