EL296D / EL297D seriesLennox E370 fault code (EL296D / EL297D)

Interlock switch sensed open for 2 min- utes.

What the manual says

Interlock switch sensed open for 2 min- utes.

Models and series

Listed for: EL296D, EL297D.

Checks from the manual

  1. Control sees the loss of 24VAC for 2 minutes.Terminate all services and wait for interlock switch to close. The alarm will clear when 24VAC is continuously sensed on DS terminal for a minimum of 10 seconds or on a power reset.

Source

EL296DFV Downflow Variable Communicating Service, p. 26

E370 | Interlock switch sensed open for 2 min-
utes. | Control sees the loss of 24VAC for 2 minutes.Terminate all services
and wait for interlock switch to close. The alarm will clear when
24VAC is continuously sensed on DS terminal for a minimum of 10
seconds or on a power reset.