EL296D / EL297D seriesLennox E312 fault code (EL296D / EL297D)
Restricted air flow in cooling or continu- ous fan mode is lower than cfm setting.
What the manual says
Restricted air flow in cooling or continu- ous fan mode is lower than cfm setting.
Models and series
Listed for: EL296D, EL297D.
Checks from the manual
- Warning Only. Restricted airflow - Indoor blower is running at a re- duced CFM (Cutback Mode - The variable speed motor has pre-set speed and torque limiters to protect the motor from damage caused by operating outside of design parameters (0 to 0.8” W.C.. total ex- ternal static pressure). Check filter and duct system. To clear, re- place filter if needed or repair/add duct. Cleared after the current service demand is satisfied.
Source
EL296DFV Downflow Variable Communicating Service, p. 26
E312 | Restricted air flow in cooling or continu- ous fan mode is lower than cfm setting. | Warning Only. Restricted airflow - Indoor blower is running at a re- duced CFM (Cutback Mode - The variable speed motor has pre-set speed and torque limiters to protect the motor from damage caused by operating outside of design parameters (0 to 0.8” W.C.. total ex- ternal static pressure). Check filter and duct system. To clear, re- place filter if needed or repair/add duct. Cleared after the current service demand is satisfied.