MMLD018-048S6S, MMPD024-048S6S Outdoor Single Zone R-32 InstructionsLennox E489 fault code
FAN #1 motor current limiting error
What the manual says
FAN #1 motor current limiting error
Source
MMLD018-048S6S, MMPD024-048S6S Outdoor Single Zone R-32 Instructions, p. 52
No. | Error Code | Meaning | Remarks 31 | E447 | Outdoor Fan#1 motor wire disconnection error | 1. Check motor connector 2. Change motor 3. Change INV PCB 32 | E455 | Outdoor Fan#1 IPM overheat error | 1. Change motor 2. Change INV PCB 33 | E458 | Fan speed error | FAN1 ERROR 34 | E461 | Error due to operation failure of inverter compressor | - 35 | E462 | System stops due to full current control | - 36 | E463 | Over current trip / PFC over current error | Check OLP sensor 37 | E464 | IPM Over Current(O.C) | 1. Check if the service valve is open 2. Check the state of refrigerant 3. Check if connecting wire and the pipe are OK 4. Check the compressor 38 | E465 | Comp. Overload error | - 39 | E466 | DC-Link voltage under/over error | Check AC Power and DC Link Voltage 40 | E467 | Error due to abnormal rotation of the compressor or unconnected wire of compressor | Check Comp wire 41 | E468 | Error on current sensor (Short or Open) | Check Outdoor Inverter PBA. 42 | E469 | Error on DC-Link voltage sensor (Short or Open) | - 43 | E470 | Outdoor unit EEPROM Read/Write error (Option) | Check Outdoor EEPROM Data 44 | E471 | Outdoor unit EEPROM Read/Write error (H/W) | Check Outdoor EEPROM PBA 45 | E474 | Error on IPM Heat Sink sensor of inverter 1 (Short or Open) | Check Outdoor Inverter PBA. 46 | E475 | Error on inverter fan 2 | FAN2 ERROR 47 | E478 | Outdoor Fan#1 motor overcurrent error | 1. Change motor 2. Change INV PCB 48 | E483 | Overvoltage of H/W detect DC link | Check AC Power 49 | E484 | PFC Overload (Over current) Error | Check Outdoor Inverter PBA. 50 | E485 | Error on input current sensor of inverter 1 (Short or Open) | Check Outdoor EEPROM PBA 51 | E486 | Outdoor Fan#1 high voltage or low voltage error | 1. Change motor 2. Change INV PCB 52 | E488 | Inverter input voltage sensor error | Check Outdoor Inverter PBA 53 | E489 | FAN #1 motor current limiting error | 1. Change motor 2. Change INV PCB
Ask about your unit
Last checked 2026-11-18 against MMLD018-048S6S, MMPD024-048S6S Outdoor Single Zone R-32 Instructions.
Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.