MMLD018-048S6S, MMPD024-048S6S Outdoor Single Zone R-32 InstructionsLennox E489 fault code

FAN #1 motor current limiting error

What the manual says

FAN #1 motor current limiting error

Source

MMLD018-048S6S, MMPD024-048S6S Outdoor Single Zone R-32 Instructions, p. 52

No. | Error
Code | Meaning | Remarks
31 | E447 | Outdoor Fan#1 motor wire disconnection error | 1. Check motor connector
2. Change motor
3. Change INV PCB
32 | E455 | Outdoor Fan#1 IPM overheat error | 1. Change motor
2. Change INV PCB
33 | E458 | Fan speed error | FAN1 ERROR
34 | E461 | Error due to operation failure of inverter compressor | -
35 | E462 | System stops due to full current control | -
36 | E463 | Over current trip / PFC over current error | Check OLP sensor
37 | E464 | IPM Over Current(O.C) | 1. Check if the service valve is open
2. Check the state of refrigerant
3. Check if connecting wire and the
pipe are OK
4. Check the compressor
38 | E465 | Comp. Overload error | -
39 | E466 | DC-Link voltage under/over error | Check AC Power and DC Link
Voltage
40 | E467 | Error due to abnormal rotation of the compressor or
unconnected wire of compressor | Check Comp wire
41 | E468 | Error on current sensor (Short or Open) | Check Outdoor Inverter PBA.
42 | E469 | Error on DC-Link voltage sensor (Short or Open) | -
43 | E470 | Outdoor unit EEPROM Read/Write error (Option) | Check Outdoor EEPROM Data
44 | E471 | Outdoor unit EEPROM Read/Write error (H/W) | Check Outdoor EEPROM PBA
45 | E474 | Error on IPM Heat Sink sensor of inverter 1 (Short or
Open) | Check Outdoor Inverter PBA.
46 | E475 | Error on inverter fan 2 | FAN2 ERROR
47 | E478 | Outdoor Fan#1 motor overcurrent error | 1. Change motor
2. Change INV PCB
48 | E483 | Overvoltage of H/W detect DC link | Check AC Power
49 | E484 | PFC Overload (Over current) Error | Check Outdoor Inverter PBA.
50 | E485 | Error on input current sensor of inverter 1 (Short or Open) | Check Outdoor EEPROM PBA
51 | E486 | Outdoor Fan#1 high voltage or low voltage error | 1. Change motor
2. Change INV PCB
52 | E488 | Inverter input voltage sensor error | Check Outdoor Inverter PBA
53 | E489 | FAN #1 motor current limiting error | 1. Change motor
2. Change INV PCB