EL296D / EL297D seriesLennox E115 fault code (EL296D / EL297D)
Low 24V - Control will restart if the error recovers.
What the manual says
Low 24V - Control will restart if the error recovers.
Models and series
Listed for: EL296D, EL297D.
Checks from the manual
- 24-Volt Power Low (Range is 18 to 30 volts). Check and correct voltage. Check for additional power-robbing equipment connected to system. May require installation of larger VA transformer to be installed in furnace / air handler. Clears after fault recovered.
Source
EL180UHNEK Upflow/Horizontal ULNOx Service, p. 11
E115 | Low 24V - Control will restart if the error recovers. | 24-Volt Power Low (Range is 18 to 30 volts). Check and correct voltage. Check for additional power-robbing equipment connected to system. May require installation of larger VA transformer to be installed in furnace / air handler. Clears after fault recovered.