Skip to content

EL296D / EL297D / ML296D / ML296U / ML297D / ML297U seriesLennox E272 fault code (EL296D / EL297D / ML296D / ML296U / ML297D / ML297U)

Soft lockout - Exceeded maximum number of recycles. Last recycle due to the pressure switch opening.

What the manual says

Soft lockout - Exceeded maximum number of recycles. Last recycle due to the pressure switch opening.

Models and series

Listed for: EL296D, EL297D, ML296D, ML296U, ML297D, ML297U.

Checks from the manual

  1. Check operation of low pressure switch to see if it is stuck closed on heat call. Check pressure (inches w.c.) of pressure switch closing on heat call. Measure operating pressure (inches w.c.). Inspect vent and combustion air inducer for correct operation and restriction. Clears when heat call finishes successfully.

Source

EL180UHNEK Upflow/Horizontal ULNOx Service, p. 13

E272 | Soft lockout - Exceeded maximum number of
recycles. Last recycle due to the pressure switch
opening. | Check operation of low pressure switch to see if it is stuck closed on
heat call. Check pressure (inches w.c.) of pressure switch closing on
heat call. Measure operating pressure (inches w.c.). Inspect vent and
combustion air inducer for correct operation and restriction. Clears
when heat call finishes successfully.
Ask about your unit

Last checked 2026-11-18 against EL180UHNEK Upflow/Horizontal ULNOx Service.

Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.