EL296D / EL297D / ML296D / ML296U / ML297D / ML297U seriesLennox E272 fault code (EL296D / EL297D / ML296D / ML296U / ML297D / ML297U)
Soft lockout - Exceeded maximum number of recycles. Last recycle due to the pressure switch opening.
What the manual says
Soft lockout - Exceeded maximum number of recycles. Last recycle due to the pressure switch opening.
Models and series
Listed for: EL296D, EL297D, ML296D, ML296U, ML297D, ML297U.
Checks from the manual
- Check operation of low pressure switch to see if it is stuck closed on heat call. Check pressure (inches w.c.) of pressure switch closing on heat call. Measure operating pressure (inches w.c.). Inspect vent and combustion air inducer for correct operation and restriction. Clears when heat call finishes successfully.
Source
EL180UHNEK Upflow/Horizontal ULNOx Service, p. 13
E272 | Soft lockout - Exceeded maximum number of recycles. Last recycle due to the pressure switch opening. | Check operation of low pressure switch to see if it is stuck closed on heat call. Check pressure (inches w.c.) of pressure switch closing on heat call. Measure operating pressure (inches w.c.). Inspect vent and combustion air inducer for correct operation and restriction. Clears when heat call finishes successfully.
Ask about your unit
Last checked 2026-11-18 against EL180UHNEK Upflow/Horizontal ULNOx Service.
Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.