EL296D / EL297D / ML296D / ML296U / ML297D / ML297U seriesLennox E240 fault code (EL296D / EL297D / ML296D / ML296U / ML297D / ML297U)

Low flame current - Run mode.

What the manual says

Low flame current - Run mode.

Models and series

Listed for: EL296D, EL297D, ML296D, ML296U, ML297D, ML297U.

Checks from the manual

  1. Check micro-amperes of flame sensor using control diagnostics or field-installed mode. Clean or replace sensor. Measure voltage of neutral to ground to ensure good unit ground. Alert clears after current heat call has been completed. See TABLE 5 for flame signal.

Source

EL180UHNEK Upflow/Horizontal ULNOx Service, p. 13

E240 | Low flame current - Run mode. | Check micro-amperes of flame sensor using control diagnostics
or field-installed mode. Clean or replace sensor. Measure voltage
of neutral to ground to ensure good unit ground. Alert clears after
current heat call has been completed. See TABLE 5 for flame
signal.