EL297D / ML296D / ML296U / ML297D / ML297U seriesLennox E154 fault code (EL297D / ML296D / ML296U / ML297D / ML297U)

Refrigerant Leak Detector Sensor #1 Communication lost or invalid sensor dip switch configuration (Disable/Enable)

What the manual says

Refrigerant Leak Detector Sensor #1 Communication lost or invalid sensor dip switch configuration (Disable/Enable)

Models and series

Listed for: EL297D, ML296D, ML296U, ML297D, ML297U.

Checks from the manual

  1. There may be an issue with the wiring harness connecting the sensor #1 to the furnace control board, either with the wiring itself or with the connector. Check the wiring and the connector for damage or improper connectivity. Check the sensor for damage or obstruction on the harness plug. This fault clears when communications with the sensor has been reestablished, but blower latches for a minimum of 5 minutes. Retest of the presence of fault can be effected by pressing the Low GWP test button on the furnace unit control board. This may also indicate incorrect Low GWP dip switch settings. Please refer to installation instructions.

Source

EL180UHNEK Upflow/Horizontal ULNOx Service, p. 12

E154 | Refrigerant Leak Detector Sensor #1
Communication lost or invalid sensor dip
switch configuration (Disable/Enable) | There may be an issue with the wiring harness connecting the
sensor #1 to the furnace control board, either with the wiring
itself or with the connector. Check the wiring and the connector
for damage or improper connectivity. Check the sensor for
damage or obstruction on the harness plug. This fault clears when
communications with the sensor has been reestablished, but
blower latches for a minimum of 5 minutes. Retest of the presence
of fault can be effected by pressing the Low GWP test button on the
furnace unit control board.
This may also indicate incorrect Low GWP dip switch settings.
Please refer to installation instructions.