Skip to content

EL21KLV | UNIT INFORMATION | Service LiteratureLennox E482 fault code

Compressor Suction Temperature sensor has malfunctioned. Check temperature sensor resistance in the applicable Installation and Service Procedure Manual. Nominal resistance is 10K ohms at 77°F. Compressor speed limited to 70 hz.

What the manual says

Compressor Suction Temperature sensor has malfunctioned. Check temperature sensor resistance in the applicable Installation and Service Procedure Manual. Nominal resistance is 10K ohms at 77°F. Compressor speed limited to 70 hz.

Source

EL21KLV | UNIT INFORMATION | Service Literature, p. 50

E482 | N/A | N/A | N/A | N/A | Compressor Suction Temperature sensor has malfunctioned. Check temperature sensor resistance
in the applicable Installation and Service Procedure Manual. Nominal resistance is 10K ohms at 77°F.
Compressor speed limited to 70 hz. |

Other Lennox codes in this family

Ask about your unit

Last checked 2026-11-18 against EL21KLV | UNIT INFORMATION | Service Literature.

Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.