EL296D / EL297D seriesLennox E290 fault code (EL296D / EL297D)

Ignitor circuit fault - Failed ignitor or triggering circuitry.

What the manual says

Ignitor circuit fault - Failed ignitor or triggering circuitry.

Models and series

Listed for: EL296D, EL297D.

Checks from the manual

  1. Measure resistance of hot surface ignitor. Replace if open or not within specifications. 1-hour soft lockout. Clears when flame has been proven stable.

Source

EL180UHNEK Upflow/Horizontal ULNOx Service, p. 13

E290 | Ignitor circuit fault - Failed ignitor or triggering
circuitry. | Measure resistance of hot surface ignitor. Replace if open or not within
specifications. 1-hour soft lockout. Clears when flame has been proven
stable.

Other Lennox codes in this family

Ask about your unit

Last checked 2026-11-18 against EL180UHNEK Upflow/Horizontal ULNOx Service.

Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.