EL296D / EL297D seriesLennox E290 fault code (EL296D / EL297D)
Ignitor circuit fault - Failed ignitor or triggering circuitry.
What the manual says
Ignitor circuit fault - Failed ignitor or triggering circuitry.
Models and series
Listed for: EL296D, EL297D.
Checks from the manual
- Measure resistance of hot surface ignitor. Replace if open or not within specifications. 1-hour soft lockout. Clears when flame has been proven stable.
Source
EL180UHNEK Upflow/Horizontal ULNOx Service, p. 13
E290 | Ignitor circuit fault - Failed ignitor or triggering circuitry. | Measure resistance of hot surface ignitor. Replace if open or not within specifications. 1-hour soft lockout. Clears when flame has been proven stable.
Other Lennox codes in this family
Ask about your unit
Last checked 2026-11-18 against EL180UHNEK Upflow/Horizontal ULNOx Service.
Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.