MMLD018-048S6S, MMPD024-048S6S Outdoor Single Zone R-32 InstructionsLennox E198 fault code
Error on thermal fuse of indoor unit (Open)
What the manual says
Error on thermal fuse of indoor unit (Open)
Source
MMLD018-048S6S, MMPD024-048S6S Outdoor Single Zone R-32 Instructions, p. 50
No. | Error Code | Meaning | Remarks 1 | E108 | Error due to duplicated communication address | Check on repeated indoor unit main address 2 | E116 | R-32 detection sensor 'Short' or 'Open' or 'Abnormal signal' error. | 1. Check R-32 sensor connector. 2. Check R-32 sensor wire. 3. Check R-32 sensor. 4. Change R-32 sensor. 3 | E118 | Indoor fan controller PCB overheat error | Check Indoor fan controller PCB 4 | E121 | Error on room temperature sensor of indoor unit (Short or Open) | Indoor unit Room Thermistor Open/ Short 5 | E122 | Error on EVA IN sensor of indoor unit (Short or Open) | Indoor unit EVA IN Thermistor _ Open/Short 6 | E123 | Error on EVA OUT sensor of indoor unit (Short or Open) | Indoor unit EVA OUT Thermistor _ Open/Short 7 | E153 | Error on float switch (2nd detection) | Indoor unit Float Switch Open/ Short Drain Pump operation Check 8 | E154 | Indoor fan error | Check on indoor unit indoor Fan operation 9 | E198 | Error on thermal fuse of indoor unit (Open) | Thermal Fuse Open Check of indoor unit Terminal Block 10 | E201 | Communication error between the indoor unit and outdoor unit (Pre-tracking failure or when the actual number of indoor units are different from the indoor unit quantity setting on the outdoor unit) Error due to communication tracking failure after initial power is supplied (The error occurs regardless of the number of units.) | Check indoor quantity setting in outdoor 11 | E202 | Communication error between indoor unit and outdoor unit (When there is no response from indoor units after tracking is completed) | Check electrical connection and setting between indoor unit and outdoor unit 12 | E203 | Communication error between the outdoor unit and main micom (For PF #4 to #6 controllers, error will be determined from the time when the compressor is turned on.) | Check electrical connection and setting between outdoor unit MAIN PBA - INVERTER PBA 13 | E205 | Main PBA - other PBA Communication error (All other PBA communication error) | 1. Check Main PBA connectors 2. Check other PBA connectors 3. Change Mian PBA
Other Lennox codes in this family
Ask about your unit
Last checked 2026-11-18 against MMLD018-048S6S, MMPD024-048S6S Outdoor Single Zone R-32 Instructions.
Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.