Skip to content

CDVS96 / GCVC96 / GD9T80 / GD9T96 / GDVM97 / GDVT80 / GDVT96 / GMVC96 / GR9S96 / GR9T80 / GR9T96 / GRVM97 / GRVT80 / GRVT96 / VR9S96 seriesGoodman EE0 fault code

Furnace lockout due to excessive number of ignition "retries" (3 total). Failure to establish flame. Loss of flame after establishment.

What the manual says

Furnace lockout due to excessive number of ignition "retries" (3 total). Failure to establish flame. Loss of flame after establishment.

Models and series

Listed for: CDVS96, GCVC96, GD9T80, GD9T96, GDVM97, GDVT80, GDVT96, GMVC96, GR9S96, GR9T80, GR9T96, GRVM97, GRVT80, GRVT96, VR9S96.

Source

Service Manual RS6612023, p. 41

Symptom | LED
Status | Fault Description | Possible Causes | Corrective Action(s) | Notes & Cautions
Furnace fails to
operate. | EE0 | Furnace lockout due
to excessive number
of ignition "retries" (3
total).
Failure to establish
flame.
Loss of flame after
establishment. | • Failure to establish flame.
Cause may be no gas to
burners, front cover pressure
switch stuck open, bad
igniter or igniter alignment,
improper orifices, or coated/
oxidized or improperly con­
nected flame sensor.
• Loss of flame after estab­
lishment. Cause may be
interrupted gas supply, lazy
burner flames (improper gas
pressure or restriction in
flue and/or combustion air
piping), front cover pressure
switch opening, or improper
induced draft blower perfor­
mance. | • Locate and correct gas inter­
ruption.
• Check front cover pressure
switch operation (hose, wiring,
contact operation). Correct if
necessary.
• Replace or realign igniter.
• Check flame sense signal.
Clean sensor if coated and/or
oxidized.
• Check flue piping for block­
age, proper length, elbows and
termination.
• Verify proper induced draft
blower performance. | • Turn power OFF prior to
repair.
• Igniter is fragile, handle
with care.
• Clean flame sensor with
steel wool.
• See "Vent/Flue Pipe"
section for piping details.