CDVS96 / GCVC96 / GD9T80 / GD9T96 / GDVM97 / GDVT80 / GDVT96 / GMVC96 / GR9S96 / GR9T80 / GR9T96 / GRVM97 / GRVT80 / GRVT96 / VR9S96 seriesGoodman EE0 fault code
Furnace lockout due to excessive number of ignition "retries" (3 total). Failure to establish flame. Loss of flame after establishment.
What the manual says
Furnace lockout due to excessive number of ignition "retries" (3 total). Failure to establish flame. Loss of flame after establishment.
Models and series
Listed for: CDVS96, GCVC96, GD9T80, GD9T96, GDVM97, GDVT80, GDVT96, GMVC96, GR9S96, GR9T80, GR9T96, GRVM97, GRVT80, GRVT96, VR9S96.
Source
Service Manual RS6612023, p. 41
Symptom | LED Status | Fault Description | Possible Causes | Corrective Action(s) | Notes & Cautions Furnace fails to operate. | EE0 | Furnace lockout due to excessive number of ignition "retries" (3 total). Failure to establish flame. Loss of flame after establishment. | • Failure to establish flame. Cause may be no gas to burners, front cover pressure switch stuck open, bad igniter or igniter alignment, improper orifices, or coated/ oxidized or improperly con nected flame sensor. • Loss of flame after estab lishment. Cause may be interrupted gas supply, lazy burner flames (improper gas pressure or restriction in flue and/or combustion air piping), front cover pressure switch opening, or improper induced draft blower perfor mance. | • Locate and correct gas inter ruption. • Check front cover pressure switch operation (hose, wiring, contact operation). Correct if necessary. • Replace or realign igniter. • Check flame sense signal. Clean sensor if coated and/or oxidized. • Check flue piping for block age, proper length, elbows and termination. • Verify proper induced draft blower performance. | • Turn power OFF prior to repair. • Igniter is fragile, handle with care. • Clean flame sensor with steel wool. • See "Vent/Flue Pipe" section for piping details.
Other Goodman codes in this family
Ask about your unit
Last checked 2026-11-18 against Service Manual RS6612023.
Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.