CDVS96 / GR9S96 / VR9S96 seriesGoodman E1E fault code (CDVS96 / GR9S96 / VR9S96)
APS pressure error
What the manual says
APS pressure error
Models and series
Listed for: CDVS96, GR9S96, VR9S96.
Source
Service Manual RS6612302, p. 33
Symptom | LED Status | Fault Description | Corrective Actions Furnace fails to operate | E1d | APS span error | Check Red, Black, White harness & connections to inducer & control board Check pressure hoses to pressure sensor and pressure switch Furnace fails to operate | E1E | APS pressure error | Check Red, Black, White harness & connections to inducer & control board Replace pressure sensor Furnace fails to operate | E1F | APS input error | Check Red, Black, White harness & connections to inducer & control board Replace pressure sensor Twinning feature not working | EEH | TWIN Error | Check for wiring connections. Replace integrated control board Furnace fails to operate and goes to hard lockout | EbL | Main blower motor is consuming very little current after heat on delay, below an expected value | Check for loose motor wiring connections. Verify if the blower motor is burnt, replace blower motor if found burnt Furnace fails to operate and goes to hard lockout | EbU | Main blower motor is consuming too much current during inducer pre-purge, above an expected value. | Verify wiring connections to and from motor are not loose. Verify that line voltage wires to the control and the main blower motor are not reversed at the control. Furnace fails to operate | Ed0 | No Shared data | Populate shared data set using BTPIM01 Furnace stops heating and only the fan is operating | EAF | Furnace has lost communication with the R-32 sensor and the furnace is in mitigation mode. | Verify wire connection to R-32 sensor is not loose. Verify that the R-32 sensor wire is not damaged. Replace R-32 Sensor. Furnace stops heating and only the fan is operating | EAL | R-32 sensor has detected a refrigerant leak and furnace is in mitigation mode. | Investigate the indoor coil for a refrigerant leak. Furnace will resume normal operation once a leak is not detected and the 5 minute delay period is over. Furnace stops heating and only the fan is operating | EAS | R-32 sensor has detected a fault and the furnace is in mitigation mode. | Investigate the R-32 sensor. Replace the R-32 sensor. Furnace stops heating and only the fan is operating | Ear | A2L relay in the furnace control board has detected a fault and the furnace is in mitigation mode. | Investigate A2L relay. Cycle power on the furnace. Replace integrated control board. Furnace fails to operate. Integrated control module LED display provides no signal | None | No 115 power to furnace or no 24 volt power to integrated control module. Blown fuse or tripped circuit breaker Integrated control module is non- functional | Restore high voltage power to furnace and integrated control module. Correct condition which caused fuse to open, replace fuse Replace non-functional integrated control module.
Other Goodman codes in this family
Ask about your unit
Last checked 2026-11-18 against Service Manual RS6612302.
Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.