CDVS96 / GR9S96 / VR9S96 seriesGoodman E1d fault code (CDVS96 / GR9S96 / VR9S96)
Analog Pressure Sensor Span Error. Inconsistent pressure reading with inducer ON
What the manual says
Analog Pressure Sensor Span Error. Inconsistent pressure reading with inducer ON
Models and series
Listed for: CDVS96, GR9S96, VR9S96.
Source
Service Manual RS6612019, p. 31
Symptom | LED Status | Fault Description | Corrective Actions Furnace operates at reduced performance or operates on low stage when high stage is expected | E | Airflow is lower than demanded | Check filters for blockage, clean filters or remove obstruction Check ductwork for blockage, remove obstruction and verify all registers are fully open Verify ductwork is appropriately sized for system, resize and/or replace ductwork if necessary Furnace fails to operate | E1 | Analog Pressure Sensor Reference Error. APS reference is out of the range (5.0+/-0.2)V for 5 seconds | Verify electrical connections to pressure sensor Furnace fails to operate | E1 | Analog Pressure Sensor Null Error. Inconsistent Pressure reading with inducer OFF | Verify electrical connections to pressure sensor Furnace fails to operate | E1d | Analog Pressure Sensor Span Error. Inconsistent pressure reading with inducer ON | Verify electrical connections to pressure sensor Furnace fails to operate | E1 | Analog Pressure Error (Blocked Vent Error) | Need to check the APS Sensor or its connection if this error is occurred. The failure conditions occur as per the following for 5 seconds: 1. The vent is blocked, and the pressure could not reach (lower than) the target pressure when inducer stayed at maximum RPM which stored in Shared Data. 2. The vent is blocked, and the pressure could not reach (higher than) the target pressure when inducer stays at the minimum RPM (Pressure Switch Min Limit). 3. APS fault causes the pressure fixed at a value lower than the target pressure when inducer stayed at maximum RPM which stored in Shared Data. 4. APS fault causes the pressure fixed at a value higher than the target pressure when inducer stayed at minimum RPM (Pressure Switch Min Limit). Furnace fails to Operate | E1 | Analog Pressure Sensor, Input Error | Check the APS Sensor or its connection if this error is occurred. APS input voltage is out of the below ranges for 5 seconds. 1. If 2" is selected, the voltage range shall be from (0.25-0.06)V to (4+0.06)V. 2. If 4" is selected, the voltage range shall be from (0.5-0.06)V to (4.5+0.06)V.
Other Goodman codes in this family
Ask about your unit
Last checked 2026-11-18 against Service Manual RS6612019.
Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.