Installation Instructions IOD-2024EGoodman E1f fault code

Analog Pressure Sensor, Input Error

What the manual says

Analog Pressure Sensor, Input Error

Source

Installation Instructions IOD-2024E, p. 29

Furnace fails to Operate | E1f | Analog Pressure Sensor, Input
Error | Check the APS Sensor or its connection if this
error is occurred. APS input voltage is out of the
below ranges for 5 seconds.
1. If 2" is selected, the voltage range shall be from
(0.25-0.06)V to (4+0.06)V.
2. If 4" is selected, the voltage range shall be from
(0.5-0.06)V to (4.5+0.06)V.