Installation Instructions IO-453BGoodman 73 fault code
Liquid side thermistor abnormality
What the manual says
Liquid side thermistor abnormality
Source
Installation Instructions IO-453B, p. 18
73 | E_73 | LIQ TEMP FLT | Liquid side thermistor abnormality | • Open (or) short circuit of the liquid thermistor (X5A) • Liquid thermistor reading incorrect or values outside the normal range | • Check the connection to liquid thermistor (PCB and junction connector) • Check the resistance value of the thermistor (refer service manual) • Replace thermistor • Replace the control board
Other Goodman codes in this family
Ask about your unit
Last checked 2026-11-18 against Installation Instructions IO-453B.
Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.