GD9T80 / GD9T96 / GR9T80 / GR9T96 seriesGoodman EEJ fault code (GD9T80 / GD9T96 / GR9T80 / GR9T96)
Inducer relay error.
What the manual says
Inducer relay error.
Models and series
Listed for: GD9T80, GD9T96, GR9T80, GR9T96.
Source
Service Manual RS6612301, p. 38
Symptom | LED Status | Fault Description | Possible Causes | Corrective Action(s) | Notes & Cautions Normal furnace op eration with weak flame signal. | EE6 | Flame sense micro amp signal is low. | • Flame sensor is coated/ oxidized. • Flame sensor incorrectly positioned in burner flame. • Lazy burner flame due to improper gas pressure or combution air. | • Clean flame sensor if coated or oxidized. • Inspect flame sensor for proper alignment. • Compare current gas pressure to rating plate and adjust as needed. | • Turn power OFF prior to repair. • Clean flame sensor with steel wool. • See “Vent/Flue Pipe” section for piping details. • See rating plate for proper gas pressure. Furnace fails to operate. | E10 | Grounding fault | • Poor neutral connection. | • Verify neutral wire connection to furnace and continuity to ground source. | • Turn power OFF prior to repair. Furnace fails to operate. | E11 | Open rollout switch. | • Gas pressure too high. • Burners mis-aligned. • Restricted heat exchang er or venting. | • Check and correct gas pressure. • Check and correct burner alignment. • Check and correct restriction | • Turn power OFF prior to repair. Furnace fails to operate. | EEA | Polarity if 115 volt AC is reversed. | • Polarity of 115 volt AC power to furnace or inte grated control module is reversed. • Poor furnace ground. | • Review wiring diagram to correct polarity. • Verify proper ground. Correct if necessary. • Check and correct wiring. | • Turn power OFF prior to repair. Furnace fails to operate. | EEb | Gas valve is not energized when it should be. External gas valve error. | • Miswired gas valve circuit. • Open gas valve circuit. • Gas valve relay on inte grated control board stuck open. | • Check wiring in gas valve circuit. • Replace integrated con trol board. | • Turn power OFF prior to repair. Furnace fails to operate. | EEC | Gas valve is energized when it should not be. Internal gas valve error. | • Miswired gas valve circuit. • Shorted gas valve wiring. • Gas valve relay on inte grated control board stuck open. | • Check wiring in gas valve circuit. • Replace integrated con trol board. | • Turn power OFF prior to repair. Furnace fails to operate. | EEE | Internal Faults or IRQ Loss in integrated control board. | | • Replace integrated con trol board. | • Turn power OFF prior to repair. Twinning feature not working. | EEH | TWIN error. | • Both furnaces not on the same 115 volt power from breaker. • Low voltage wiring error or loose wiring connec tions. | • Verify 115 volt power to each furnace. • Check wiring connec tions. • Replace integrated con trol board if necessary. | • Turn power OFF prior to repair. Furnace fails to operate. | EEJ | Inducer relay error. | | • Replace integrated con trol board | • Turn power OFF prior to repair. • Replace the inte grated control board with proper replace ment part.
Ask about your unit
Last checked 2026-11-18 against Service Manual RS6612301.
Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.