CDVS96 / GCVC96 / GD9T80 / GD9T96 / GDVM97 / GDVT80 / GDVT96 / GMVC96 / GR9S96 / GR9T80 / GR9T96 / GRVM97 / GRVT80 / GRVT96 / VR9S96 seriesGoodman EEA fault code
Polarity of 115 volt AC is reversed Poor unit ground
What the manual says
Polarity of 115 volt AC is reversed Poor unit ground
Models and series
Listed for: CDVS96, GCVC96, GD9T80, GD9T96, GDVM97, GDVT80, GDVT96, GMVC96, GR9S96, GR9T80, GR9T96, GRVM97, GRVT80, GRVT96, VR9S96.
Source
Service Manual RS6612019, p. 33
Symptom | LED Status | Fault Description | Corrective Actions Induced draft blower and circulator blower runs continuously No furnace operation | EE | Flame sensed with no call for heat Short to ground in flame sense circuit Lingering burner flame Slow closing gas valve | Correct short at flame sensor or in flame sensor wiring Check for lingering or lazy flame Verify proper operation of gas valve No furnace operation | EE | Open fuse Short in low voltage wiring | Replace fuse Locate and correct short in low voltage wiring Normal furnace operation | EE | Flame sense micro amp signal is low Flame sensor is coated/oxidized Flame sensor incorrectly positioned in burner fame Lazy burner flame due to improper gas pressure or combustion air | Clean flame sensor if coated or oxidized Inspect for proper flame sensor alignment Check inlet air piping for blockage, proper length, elbows, and termination Compare current gas pressure to rating plate and adjust as needed Furnace fails to operate | EE | Problem with igniter circuit Improperly connected or shorted igniter Poor unit ground Igniter relay fault on integrated control module | Check and correct wiring from integrated control module to igniter Diagnose and replace shorted igniter as needed Verify and correct unit ground wiring if needed Check igniter output from control, replace if necessary Furnace fails to operate on high stage; furnace operates normally on low stage Induced draft blower operating | EE | High stage pressure switch circuit is closed at start of heating cycle. High stage pressure switch contacts sticking Shorts in pressure switch circuit wiring | Diagnose and replace high stage pressure switch if needed Repair short in wiring Furnace fails to operate on high stage; furnace operates normally on low stage Induced draft blower operating | EE | High stage pressure switch circuit is not closed Furnace is operating on low stage only | Inspect pressure switch hose, repair/replace if necessary Inspect flue and/or inlet air piping for blockage, proper length, elbows, and termination Check drain system, correct as necessary Check induced draft blower performance, correct as necessary Tighten or correct wiring connection Furnace fails to operate | EEA | Polarity of 115 volt AC is reversed Poor unit ground | Correct polarity, check and correct wiring if necessary Verify proper ground, correct if necessary Furnace fails to operate | EE | Gas valve is not energized when it should be External Gas Valve Error | Check wiring in gas valve circuit Replace integrated control board Furnace fails to operate | EEC | Gas valve is energized when it should not be Internal gas valve error | Check wiring in gas valve circuit Replace integrated control board
Ask about your unit
Last checked 2026-11-18 against Service Manual RS6612019.
Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.