CDVS96 / GCVC96 / GD9T80 / GD9T96 / GDVM97 / GDVT80 / GDVT96 / GMVC96 / GR9S96 / GR9T80 / GR9T96 / GRVM97 / GRVT80 / GRVT96 / VR9S96 seriesGoodman EE1 fault code
Low stage pressure switch circuit is closed at start of heating cycle Low stage pressure switch contacts sticking Short in pressure switch circuit wiring
What the manual says
Low stage pressure switch circuit is closed at start of heating cycle Low stage pressure switch contacts sticking Short in pressure switch circuit wiring
Models and series
Listed for: CDVS96, GCVC96, GD9T80, GD9T96, GDVM97, GDVT80, GDVT96, GMVC96, GR9S96, GR9T80, GR9T96, GRVM97, GRVT80, GRVT96, VR9S96.
Source
Service Manual RS6612019, p. 32
Symptom | LED Status | Fault Description | Corrective Actions Furnace fails to operate | E1 | Grounding fault Poor neutral connection | Verify neutral wire connection to furnace & continuity to ground source Furnace fails to operate | E11 | Open roll out switch | Check for correct gas pressure Check for correct burner alignment Check for and correct burner restriction Furnace fails to operate | Ed | Data not yet on network | Populate shared data set using memory card Operation different than expected or no operation | Ed1 | Invalid memory card data | Verify shared data set is correct for the specific model, re-populate data using correct memory card if required Furnace fails to operate | EE | Furnace lockout due to an excessive number of ignition “retries” (3 total) Failure to establish flame Loss of flame after establishment | Locate and correct gas interruption Check front cover pressure switch operation and verify proper drainage (hose, wiring, contact operation), correct if necessary Replace or realign igniter Check flame sense signal, sand sensor if coated and/or oxidized Check flue piping for blockage, proper length, elbows, and termination Verify proper induced draft blower performance Furnace fails to operate | EE1 | Low stage pressure switch circuit is closed at start of heating cycle Low stage pressure switch contacts sticking Short in pressure switch circuit wiring | Replace low stage pressure switch Repair short in wiring Induced draft blower runs continuously with no furnace operation | EE2 | Low stage pressure switch circuit is not closed Pressure switch hose blocked pinched, or connected improperly Blocked flue and/or inlet air pipe, blocked drain system or weak induced draft blower Incorrect pressure switch set point or malfunctioning switch contacts Loose or improperly connected wiring | Inspect pressure switch hose, repair/replace if necessary Inspect flue and/or inlet air piping for blockage, proper length, elbows, and termination Check drain system, correct as necessary Check induced draft blower performance, correct as necessary Check pressure switch operation, replace as needed Tighten or correct wiring connection Circulator blower runs continuously No furnace operation | EE | Primary limit circuit is open Insufficient conditioned air over the heat exchanger Blocked filters, restrictive ductwork, improper circulator blower speed, or failed circulator blower motor Loose or improperly connected wiring in high limit circuit | Check filters and ductwork for blockage Clean filters or remove obstruction Check circulator blower speed and performance Correct speed or replace blower motor if necessary Tighten or correct wiring connection
Other Goodman codes in this family
Ask about your unit
Last checked 2026-11-18 against Service Manual RS6612019.
Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.