resi gf a80ds2vk installationmanualArmstrong Air E370 fault code

Interlock switch sensed open for 2 minutes.

What the manual says

Interlock switch sensed open for 2 minutes.

Checks from the manual

  1. Control sees the loss of 24VAC for 2 minutes.Terminate all services and wait for interlock switch to close. The alarm will clear when 24VAC is continuously sensed on DS terminal for a minimum of 10 seconds or on a power reset.

Source

resi gf a80ds2vk installationmanual, p. 42

E370 | Interlock switch sensed open for 2 minutes. | Control sees the loss of 24VAC for 2 minutes.Terminate all services and
wait for interlock switch to close. The alarm will clear when 24VAC is
continuously sensed on DS terminal for a minimum of 10 seconds or on a
power reset.