resi gf a80ds2vk installationmanualArmstrong Air E312 fault code

Restricted air flow in cooling or continuous fan mode is lower than cfm setting.

What the manual says

Restricted air flow in cooling or continuous fan mode is lower than cfm setting.

Checks from the manual

  1. Warning Only. Restricted airflow - Indoor blower is running at a reduced CFM (Cutback Mode - The variable speed motor has pre-set speed and torque limiters to protect the motor from damage caused by operating out- side of design parameters (0 to 0.8” W.C.. total external static pressure). Check filter and duct system. To clear, replace filter if needed or repair/add duct. Cleared after the current service demand is satisfied.

Source

resi gf a80ds2vk installationmanual, p. 42

E312 | Restricted air flow in cooling or continuous fan
mode is lower than cfm setting. | Warning Only. Restricted airflow - Indoor blower is running at a reduced
CFM (Cutback Mode - The variable speed motor has pre-set speed and
torque limiters to protect the motor from damage caused by operating out-
side of design parameters (0 to 0.8” W.C.. total external static pressure).
Check filter and duct system. To clear, replace filter if needed or repair/add
duct. Cleared after the current service demand is satisfied.