resi gf a80ds2vk installationmanualArmstrong Air E312 fault code
Restricted air flow in cooling or continuous fan mode is lower than cfm setting.
What the manual says
Restricted air flow in cooling or continuous fan mode is lower than cfm setting.
Checks from the manual
- Warning Only. Restricted airflow - Indoor blower is running at a reduced CFM (Cutback Mode - The variable speed motor has pre-set speed and torque limiters to protect the motor from damage caused by operating out- side of design parameters (0 to 0.8” W.C.. total external static pressure). Check filter and duct system. To clear, replace filter if needed or repair/add duct. Cleared after the current service demand is satisfied.
Source
resi gf a80ds2vk installationmanual, p. 42
E312 | Restricted air flow in cooling or continuous fan mode is lower than cfm setting. | Warning Only. Restricted airflow - Indoor blower is running at a reduced CFM (Cutback Mode - The variable speed motor has pre-set speed and torque limiters to protect the motor from damage caused by operating out- side of design parameters (0 to 0.8” W.C.. total external static pressure). Check filter and duct system. To clear, replace filter if needed or repair/add duct. Cleared after the current service demand is satisfied.
Other Armstrong Air codes in this family
Ask about your unit
Last checked 2026-11-18 against resi gf a80ds2vk installationmanual.
Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.