Installation Manual: HMCG2 Series - 16 SEER2 Horizontal Discharge Modulating Air ConditionerYork 49 fault code

Outdoor DC fan motor fault (lower fan motor)

What the manual says

Outdoor DC fan motor fault (lower fan motor)

Checks from the manual

  1. 1. The DC fan motor connection is poor. 2. The wiring to the DC fan motor has failed. 3. The DC fan motor has failed. 4. The drive circuit of the lower DC fan motor has failed. 5. Outdoor airflow blockage. | 1. Replace the DC fan motor wiring. 2. Replace the DC fan motor. 3. Replace the DC fan motor. 4. Replace the drive board of the fan motor. 5. Resolve the outdoor unit airflow restriction. |

Source

Installation Manual: HMCG2 Series - 16 SEER2 Horizontal Discharge Modulating Air Conditioner, p. 36

49 | Outdoor DC fan
motor fault (lower fan
motor) | 1. The DC fan motor
connection is poor.
2. The wiring to the DC
fan motor has failed.
3. The DC fan motor has
failed.
4. The drive circuit of the
lower DC fan motor has
failed.
5. Outdoor airflow
blockage. | 1. Replace the DC fan
motor wiring.
2. Replace the DC fan
motor.
3. Replace the DC fan
motor.
4. Replace the drive
board of the fan
motor.
5. Resolve the outdoor
unit airflow restriction. |