Installation Manual: HMCG2 Series - 16 SEER2 Horizontal Discharge Modulating Air ConditionerYork 13 fault code

Compressor overheat protector device

What the manual says

Compressor overheat protector device

Checks from the manual

  1. 1. The wiring of the overload protector has a poor connection. 2. Overload protector failure. 3. Low refrigerant charge. 4. Long lineset length applied without additional charge. 5. TXV valve failure. 6. Outdoor control board failure. | 1. Reconnect the wiring of the overload protector. 2. Replace the overload protector. 3. Check the braze joints for leaks and recharge the refrigerant. 4. Add refrigerant. 5. Replace the expansion valve. 6. Replace the outdoor control board. |

Source

Installation Manual: HMCG2 Series - 16 SEER2 Horizontal Discharge Modulating Air Conditioner, p. 33

13 | Compressor overheat
protector device | 1. The wiring of the
overload protector has
a poor connection.
2. Overload protector
failure.
3. Low refrigerant charge.
4. Long lineset length
applied without
additional charge.
5. TXV valve failure.
6. Outdoor control board
failure. | 1. Reconnect the wiring
of the overload
protector.
2. Replace the overload
protector.
3. Check the braze joints
for leaks and recharge
the refrigerant.
4. Add refrigerant.
5. Replace the expansion
valve.
6. Replace the outdoor
control board. |