FPHFR09A3D / FPHFR12A3D / FPHFR18A3D / FPHFR24A3D / FPHFR36A3D / FPHMR18A3D / FPHMR27A3D / FPHMR36A3D / FPHMR42A3D seriesRheem 13 fault code
Compressor overheat protector device
What the manual says
Compressor overheat protector device
Models and series
Listed for: FPHFR09A3D, FPHFR12A3D, FPHFR18A3D, FPHFR24A3D, FPHFR36A3D, FPHMR18A3D, FPHMR27A3D, FPHMR36A3D, FPHMR42A3D.
Checks from the manual
- 1. The wiring of the overload protector is connected loosely. 2. The overload protector fails . 3. The refrigerant is low. 4. The installation pipe is much longer than the normal one, but extra refrigerant is not added ; 5. The expansion valve fails; 6. The outdoor Main PCB has failed. | 1. Reconnect the wiring of the overload protector;. 2. Replace the overload protector. 3. Using an A2L approved leak detector, Check the braze points of the unit to confrim there are no leaks, then recharge the refrigerant;. 4. Add the refrigerant, refer to refrigerant Charging methods. 5. Replace expansion valve. 6. Replace the outdoor Main PCB.
Source
Service Manual - Ductless Floating Air® Multi-Zone R-454B Refrigerant (Wall Mounted Unit / Outdoor Unit / Cassette / Ducted), p. 193
13 | Compressor overheat protector device | 1. The wiring of the overload protector is connected loosely. 2. The overload protector fails . 3. The refrigerant is low. 4. The installation pipe is much longer than the normal one, but extra refrigerant is not added ; 5. The expansion valve fails; 6. The outdoor Main PCB has failed. | 1. Reconnect the wiring of the overload protector;. 2. Replace the overload protector. 3. Using an A2L approved leak detector, Check the braze points of the unit to confrim there are no leaks, then recharge the refrigerant;. 4. Add the refrigerant, refer to refrigerant Charging methods. 5. Replace expansion valve. 6. Replace the outdoor Main PCB.
Ask about your unit
Last checked 2026-11-18 against Service Manual - Ductless Floating Air® Multi-Zone R-454B Refrigerant (Wall Mounted Unit / Outdoor Unit / Cassette / Ducted).
Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.