CVA9, HVA9, TVA9, CVH8, HVH8, TVH8 R-410A Variable-Speed Split System Air Conditioner & Heat Pump Service ManualComfortmaker 25 fault code

INVALID MODEL PLUG/INVERTER SIZE

What the manual says

INVALID MODEL PLUG/INVERTER SIZE

Checks from the manual

  1. INVALID MODEL PLUG/INVERTER SIZE | NA | Both | Missing model plug | Install the correct model plug | | | | | Wrong Model Plug Installed | Verify correct model plug installed | | | | | Damaged Model Plug | Check model plug for corrosion or breakage; replace if necessary. Check Model Plug resistance per the wiring diagram | | | | | Model Plug not fully engaged on board | Align per the silkscreen layout | | | | | Incorrect Model Plug with Inverter Size | Replace plug or inverter with correct size (If model plug is for 2 Ton but Inverter is 3 Ton, fault code 25 will be shown) | | | | | Damaged AOC

Source

CVA9, HVA9, TVA9, CVH8, HVH8, TVH8 R-410A Variable-Speed Split System Air Conditioner & Heat Pump Service Manual, p. 14

25 | System
Malfunction | INVALID MODEL
PLUG/INVERTER SIZE | NA | Both | Missing model plug | Install the correct model plug
 |  |  |  |  | Wrong Model Plug
Installed | Verify correct model plug installed
 |  |  |  |  | Damaged Model Plug | Check model plug for corrosion or breakage;
replace if necessary. Check Model Plug
resistance per the wiring diagram
 |  |  |  |  | Model Plug not fully
engaged on board | Align per the silkscreen layout
 |  |  |  |  | Incorrect Model Plug
with Inverter Size | Replace plug or inverter with correct size (If model
plug is for 2 Ton but Inverter is 3 Ton, fault code 25
will be shown)
 |  |  |  |  | Damaged AOC