CVA9, HVA9, TVA9, CVH8, HVH8, TVH8 R-410A Variable-Speed Split System Air Conditioner & Heat Pump Service ManualComfortmaker 25 fault code
INVALID MODEL PLUG/INVERTER SIZE
What the manual says
INVALID MODEL PLUG/INVERTER SIZE
Checks from the manual
- INVALID MODEL PLUG/INVERTER SIZE | NA | Both | Missing model plug | Install the correct model plug | | | | | Wrong Model Plug Installed | Verify correct model plug installed | | | | | Damaged Model Plug | Check model plug for corrosion or breakage; replace if necessary. Check Model Plug resistance per the wiring diagram | | | | | Model Plug not fully engaged on board | Align per the silkscreen layout | | | | | Incorrect Model Plug with Inverter Size | Replace plug or inverter with correct size (If model plug is for 2 Ton but Inverter is 3 Ton, fault code 25 will be shown) | | | | | Damaged AOC
Source
CVA9, HVA9, TVA9, CVH8, HVH8, TVH8 R-410A Variable-Speed Split System Air Conditioner & Heat Pump Service Manual, p. 14
25 | System Malfunction | INVALID MODEL PLUG/INVERTER SIZE | NA | Both | Missing model plug | Install the correct model plug | | | | | Wrong Model Plug Installed | Verify correct model plug installed | | | | | Damaged Model Plug | Check model plug for corrosion or breakage; replace if necessary. Check Model Plug resistance per the wiring diagram | | | | | Model Plug not fully engaged on board | Align per the silkscreen layout | | | | | Incorrect Model Plug with Inverter Size | Replace plug or inverter with correct size (If model plug is for 2 Ton but Inverter is 3 Ton, fault code 25 will be shown) | | | | | Damaged AOC
Other Comfortmaker codes in this family
Ask about your unit
Last checked 2026-11-18 against CVA9, HVA9, TVA9, CVH8, HVH8, TVH8 R-410A Variable-Speed Split System Air Conditioner & Heat Pump Service Manual.
Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.