RESI GASFURNACES A931E-92G1E-DOWNFLOW INSTALLATIONMANUALArmstrong Air On fault code
Board Fault Detected
What the manual says
Board Fault Detected
Source
RESI GASFURNACES A931E-92G1E-DOWNFLOW INSTALLATIONMANUAL, p. 37
On | Board Fault Detected Fast Heartbeat3 | Call for Heat / Burner Operation Slow Heartbeat1 | Normal Operation – Idle, Continuous Fan, or Cool 1 Flash2 | Reverse Line Voltage Polarity or Phasing of 120V power 2 Flashes2 | Improper earth ground 3 Flashes2 | Burner failed to light, or lost flame during heat demand 4 Flashes2 | Low flame signal - check flame sensor 5 Flashes2 | Watchguard – burner failed to light, exceeded maximum number of retries/recycles, 1 hour lockout 6 Flashes2 | Not used 7 Flashes2 | Primary or Secondary limit switch open or Watchguard mode – Limit Switch open longer than 3 minutes 8 Flashes2 | Rollout switch open 9 Flashes2 | Pressure switch failed to close or opened during heat demand 10 Flashes2 | Watchguard - Pressure switch opened 5 times during one heat demand 11 Flashes2 | Pressure switch stuck closed prior to activation of combustion air inducer 12 Flashes2 | Flame sensed without gas valve energized 13 Flashes2 | Low line voltage 1 A slow heartbeat is indicated by 1 sec on / 1 sec off. It is used for idle, continuous fan and cool modes. 2 Error codes are indicated by a “rapid flash” - the LED flashes X times at 1/2 sec on / 1/2 sec off, remains off for 2 sec, then repeats. 3 A fast heartbeat is indicated by 1/2 sec on / 1/2 sec off. It is only used during a heat call. NOTE: Last 10 error codes are stored in memory, including when power is shut off to the unit. To recall, press and release button. Most recent will be displayed first, LED off for 3 sec, then next error code is displayed, etc. To clear error codes, depress and hold button longer than 5 sec. |
Ask about your unit
Last checked 2026-11-18 against RESI GASFURNACES A931E-92G1E-DOWNFLOW INSTALLATIONMANUAL.
Safety: disconnect power before opening the unit. Gas, high voltage and refrigerant work belongs to a licensed technician.